Hyperchlorination Services

Cooling Tower

CE Water can perform hyperchlorination services to disinfect recirculating cooling systems periodically or on an emergency basis.

Many of our clients use us for hyperchlorination when:

  • Legionella Concentration: >100 CFU/mL
  • ATP: > 400 RLU regularly
  • Total Aerobic Bacteria: >100,000 CFU/ML regularly

*These are examples of hyperchlorination schedules:

  • Monthly/Quarterly; if warranted, considering process situations with operational leaks and/or heavy biofouling
  • Emergency; when excessive levels of contamination are detected through testing
  • Shut-Down; prior to shutting down & laying up cooling systems
  • Resume Operations: prior to resuming operation for systems laid-up wet

CE Water‘s technicians will; select the appropriate biocides and corrosion inhibitors, calculate dosages and recirculation times, develop safety procedures, and oversee the actual application of the biocide(s). Additionally, joint decisions will be made regarding performing hyperchlorination services off-line or on-line, factoring in all safety and operational precautions.

*CE will review your facility needs and make specialized recommendations for your applications.